How to Make a PTZ Camera AS20R/AS30R Series Return to Its Preset Position After Auto-Tracking

If your AirLink PTZ camera stays where it stopped after auto-tracking, its Idle Action is switched off. Save your home view as preset 1, then call preset 105 and preset 101. The camera will then return home by itself after it has been idle.
Applies to: AirLink PTZ cameras that use the Quick Command preset set
Why the camera does not return
Auto-tracking follows a person and stops wherever that person leaves the view. Returning to a home position is a separate feature, the Idle Action, and it is off by default.
Preset 1 is the home (guard) position used by the Idle Action.
Preset 105 switches the Idle Action on.
Preset 101 tells the Idle Action to go to preset 1.
Before you start
All steps use the Preset panel in the camera's web interface: choose a number from the list (1 to 255), then click Add to save it or Call to run it.
Set up the return to home
Turn the camera to the view you want as home. Select preset 1 and click Add.
Select 105 and click Call to switch the Idle Action on.
Select 101 and click Call to set the action to "go to preset 1".
Optional: to change the idle time (90 seconds by default), select 117 and click Add, then select the number of seconds (1 to 254) and click Add.
Select 1 and click Call to confirm the home view is still correct.
To switch the Idle Action off later, select 105 and click Add.
Do not call 102, 103 or 104 afterwards. They change the Idle Action to a 360 degree scan, a limit scan or a cruise.
Test it
Turn the camera away from home, or let it track a person.
Leave it alone. If it is tracking, wait for tracking to end, then for the idle time.
The camera should return to the home view on its own.
Troubleshooting
The camera never returns. The Idle Action is still off. Call 105, then call 101.
It returns to the wrong view. Preset 1 was saved elsewhere or overwritten. Turn to the home view, select 1 and click Add.
It starts scanning or cruising instead. The Idle Action is set to 102, 103 or 104. Call 101.
It returns too late or too early. Change the idle time (step 4), then check preset 1.
All presets are gone. A factory reset (call 115) or delete-all (call 33) was run. Repeat the setup.
Preset numbers to keep free
Keep your home view on preset 1, and save other views on numbers 200 to 250. Many other numbers run camera functions instead of moving to a position: 33, 35 to 38, 41 to 48, 51 to 58, 60 to 64, 81 to 88, 92 to 94, 96 to 105, 110, 111, 113 to 115, 117, 252 and 253. The full list is in the Quick Command for PTZ Camera

























Comments